Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
RGO (Porto Alegre) ; 56(3): 315-319, jul.-set. 2008. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-495238

RESUMO

Objetivo: Avaliar o comportamento das próteses implanto-suportadas confeccionadas pela técnica do cilindro cimentado utilizando três marcas comerciais de cimentos resinosos. Métodos: Foram avaliados 53 pacientes, sendo 26 do sexo feminino e 27 do sexo masculino, com idades entre 25 a 82 anos. Resultados: Reabilitações parciais (54,43%) e totais (45,57%) sobre implantes do tipo hexágono externo, interno ou cone morse (Neodent ®, Curitiba, Brasil), totalizando 237 fixações. Os cimentos utilizados foram Panavia® (21,94%), EnForce® (58,23%) e Rely X® (19,83%). O tempo em uso das reabilitações variou de 1 a 5 anos. Considerando todas as reabilitações, foram observados 5 cilindros (2,1%) soltos; 2 implantes (0,48%) foram perdidos após o primeiro ano em carga, 16 parafusos de retenção (6,75%) da prótese estavam soltos e 31 parafusos do pilar (13,08%) desapertados. Conclusão: As prováveis causas relacionadas as falhas foram falta de retenção interna na estrutura metálica, padrão oclusal, técnica de cimentação e condição de carga. A técnica do cilindro cimentado apresentou ser efetiva quando empregada em reabilitações parciais e totais implanto-suportadas, mantendo a estabilidade protética dos componentes envolvidos, independente do cimento utilizado, porém, mais estudos clínicos devem ser realizados.


Objective: Evaluate the behavior of implant-supported dentures and their components, made by cemented cylinder technique, using three types of resin cements. Methods: Fifty three patients, of whom 26 were women and 27 men, aged between 25 and 82 years. Results: With partial (54.43%) and total (45.57%) implant-supported dentures, of the Cone Morse, external and internal hexagon types (Neodent®, Curitiba, Brazil), totaling 237 fixations, were analyzed. The resin cements used were Panavia® (21.94%), EnForce® (58.23%) and Rely X® (19.83%) and the components were used in accordance with the Laboratory Immediate Loading - Neodent® sequence. The period of time of denture use ranged between 1 and 5 years. The results reported that 5(2.1%) cylinders were loosened from metal structure (both belonging to Rely X group), 2(0.48%) implants were lost after the first year of use, 16(6.75%) denture retention screws were loosened and 31(13.08%) abutment screws were unloosened. Conclusion: The reasons for these failures probably are: metal structure internal retention failure, occlusal pattern, cementation technique and loading conditions. The cemented cylinder technique was effective when used in partial and total implant-supported rehabilitations, keeping prosthetic components stable, despite the resin cement utilized. However, further clinical studies must be conducted.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Prótese Dentária Fixada por Implante , Prótese Total , Prótese Parcial Fixa , Cimentos de Resina , Estudos Retrospectivos , Retenção de Dentadura/métodos
2.
HB cient ; 4(1): 22-5, jan.-abr. 1997. tab
Artigo em Português | LILACS | ID: lil-214111

RESUMO

O níquel, administrado intraperitonealmente na rata prenhe, no 10º dia de prenhez resultou em peso fetal diminuído, glândulas nasais pequenas, com núcleos mais alongados.


Assuntos
Animais , Feminino , Gravidez , Ratos , Feto/efeitos dos fármacos , Mucosa Nasal/citologia , Mucosa Nasal/efeitos dos fármacos , Níquel/farmacologia , Cariometria , Ratos Wistar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...